Sign In | Join Free | My xpandrally.com
China Melan Measurement & Control Instruments (Shanghai) Co.,Ltd. logo
Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
MELAN MEASUREMENT & CONTROL INSTRUMENTS (SHANGHAI) CO., LTD.
Active Member

5 Years

Home > Electromagnetic Flow Meter >

Compact Type Electromagnetic Water Flow Meter Low Flow Rate 0.6MPa~4.0MPa

Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.

Compact Type Electromagnetic Water Flow Meter Low Flow Rate 0.6MPa~4.0MPa

  • 1
  • 2

Model Number : MLF

Place of Origin : China

MOQ : 1pc

Price : Negotiation

Payment Terms : T/T

Supply Ability : 500pcs per month

Delivery Time : 7-10 working days

Packaging Details : In Carton or Wooden Box

Product Name : Electromagnetic Flow Meter

Pipeline Diameter : DN15-DN2000

Accuracy : 0.5% or 0.2%

Flange : GB/ANSI/JIS/BS/Others

Pressure Rate : 0.6MPa-4.0Mpa

IP Class : IP65/IP67/IP68

Contact Now

0.6MPa~4.0MPa Compact Type Electromagnetic Flow Meter Low Flow Rate for Water Works

1. Introduction

MLF electromagnetic flowmeter is based on Faraday's law of electromagnetic induction and consists of sensors and converters. Used to measure the conductivity of a liquid or solid. Generally, its conductivity should be greater than 5μS/cm (the conductivity of tap water, raw water is about 100~500μS/cm). it can also be used to measure various media such as acid, alkali, brine, pulp or pulp and other medium. But these medium can not contain a large number of magnetic substances and bubbles.

MLF electromagnetic flowmeter is an instrument to measure liquid fluidity. Widely used in metallurgy, chemical, paper, environmental protection, petroleum, textile, food, urban management, water plants and other industries of flow measurement.

2. Quick Details

MLF electromagnetic flowmeter is explosion-proof design.

Function of low conductivity measurement.

There are nine language options to meet the needs of different customers.

It has the function of self-regulation and self-examination.

Different outputs are optional: Hart,RS485 Profibus,4-20mA, frequency, pulse.

3. Specification

MLF Type Divided Type Integrated Type Explosive Proof Integrated Type Battery Powered Type Heat Energy Type
Accuracy ±0.2% or ±0.5%
Pipeline Diameter DN10-DN2000 DN10-DN600 DN25-DN2000
Flange GB, ANSI, JIS, BS, Others
Pressure DN10-DN600 1.0 1.6 2.5 4.0MPa
DN700-DN2000 0.6 1.0 1.6MPa
Liner Material CR, PTFE, PU, Hard Rubber, PFA, FEP(F46)
Conductivity ≥5µs/cm(Please contact us if it is less than 5µs/cm)
Electrode 316L SS, Hb, Ta, Ti, Hc, Tungsten Carbide, Others
Protection Class IP65, IP66, IP67, IP68
Medium Temperature -25~180
(Please refer to liner material)
-25~80(Please refer to liner material) -25~180
(Please refer to liner material)
Ambient Temperature for Accuracy Influence <±0.1%/10 or <±0.25%/10 at the ambient temperature of -25~60
Repetability ≤±0.1% or ±0.25%
Analog Output Error ≤±0.02mA
Velocity 0.3~10m/s
Electrical connection M20x1.5 Seal Cartridge, GB1/2, NPT1/2
Output 4-20mA, Pulse, RS485, Hart, Profibus

4. Dimensional Sketches

a. Dimension of Converter

Compact Type Electromagnetic Water Flow Meter Low Flow Rate 0.6MPa~4.0MPa

Divided Type

Compact Type Electromagnetic Water Flow Meter Low Flow Rate 0.6MPa~4.0MPa

Integrated Type

Compact Type Electromagnetic Water Flow Meter Low Flow Rate 0.6MPa~4.0MPa

Battery Powered Type

b. Dimension of Sensor

Compact Type Electromagnetic Water Flow Meter Low Flow Rate 0.6MPa~4.0MPa

Pipeline Diameter Dimension
L W H
15 160 95 130
20 160 105 137
25 160 115 150
32 160 135 160
40 200 145 175
50 200 160 185
65 200 180 205
80 200 195 215
100 250 215 235
125 250 245 275
150 300 280 300
200 350 335 355
250 400 400 405
300 500 455 460
350 500 515 520
400 600 575 580
450 600 635 630
500 600 710 685
600 600 835 795
700 700 905 910
800 800 1020 1030
900 900 1120 1120
1000 1000 1245 1250
1200 1200 1465 1470

5. Configuration

MLF Series Electromagnetic Flow Meter Configuration
Model MLF
Sensor Installation S Flange Type Sensor
C Insertion Type Sensor
O Others
Pipeline Diameter 10 10mm
15 15mm
20 20mm
......
2000 2000mm
Electrode Installation F Standard Fixed Type
Electrode Material A 316L SS
B Hb
C Ta
D Ti
E Hc
F Tungsten Carbide
G Others
Liner Material R Rubber
P PTFE
O Others
Pipe Material B 304 SS (Standard)
C 316 SS
Flange Type G GB (Standard)
A ANSI
J JIS
B BS
O Others
Flange Material A 304 SS
B 316 SS
C #20 Carbon Steel (Standard)
Cover Material D 304 SS
E 316 SS
F Carbon Steel+ Epoxy Metallic Paint (Standard)
Matching Flange 0 Without Matching Flange (Standard)
1 With Matching Flange
Ground Ring 0 Without Ground Ring (Standard)
1 With Ground Ring
Rated Pressure 10 1.0MPa
16 1.6MPa
25 2.5MPa
40 4.0MPa
Working Temperature E ≤60℃
H ≤180℃(Divided Type)
Type I Integrated Type
D Divided Type
Output P Pulse
A 4-20mA
G RS485
H Hart
Q Others
Power Supply 0 220VAC
1 24VDC
2 Battery-powered
Protection Class 0 IP65 (Integrated/Divided Type)
1 IP67 (Divided Type)
2 IP68 (Divided Type)
Other Features R Heat Energy Function
P With PT1000
B Without PT1000
Explosion Proof 0 None
EX Explosive Proof

6. Instrument Detection & Maintenance

Electromagnetic flowmeter has self-diagnosis function. In addition to power supply and hardware circuit faults, the system also alarms other faults in general use. These messages give corresponding tips in the lower right corner of the screen.

1 Maintenance and repair

A) the sensor installation site shall meet the requirements of section 4, and please keep the housing clean and tidy;

B) The transmitter shall be placed in a clean, ventilated and dry place;

C) it needs to be checked every two years. for high-precision users, the instrument needs to be submitted for review.

2 Transportation and storage

A) the instrument must be packed before transportation and handled with care.

B) The storage place must be dry and ventilated to avoid corrosive gas erosion, and the ambient temperature should not be too low or too high;

C) the storage time should not exceed three years.

3. Unpacking inspection

A) the package cannot be opened with a heavy hammer, so be careful not to damage the instrument.

B) carefully check the contents according to the packing list.


Product Tags:

electromagnetic type flow meter

      

electronic magnetic flow meter

      
Wholesale Compact Type Electromagnetic Water Flow Meter Low Flow Rate 0.6MPa~4.0MPa from china suppliers

Compact Type Electromagnetic Water Flow Meter Low Flow Rate 0.6MPa~4.0MPa Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Melan Measurement & Control Instruments (Shanghai) Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)